Home›Repair guides›Kohler›Breaker Point Gap Adjustment

Kohler — Breaker Point Gap Adjustment

Adjustments · Breaker points

From a Kohler service manual covering: KT17, KT17 Series II, KT19 Series II, KT21, Kt19. Check it applies to your exact model before use.

Applies to: Kohler Kt19

Procedure

  1. Loosen point gap adjustment screw.
  2. Readjust gap to .020" fully open.
  3. Gap may vary .017"-.023" to achieve smoothest running.
  4. Securely tighten adjusting screw after timing.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Gap .020" fully open; range .017"-.023"

Full service-parts list: Kohler Kt19 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →