Home›Repair guides›Kohler›Bleeding the Fuel System

Kohler — Bleeding the Fuel System

Maintenance

From a Kohler service manual covering: 10CC, 7CCFO, 7CCO. Check it applies to your exact model before use.

Applies to: Kubota D905BG-2 engine, Kubota V1305BG-2 engine

Before you start

  • Explosive fuel vapors. Use a container to catch fuel; wipe up all spilled fuel.

Procedure

  1. Fill the fuel tank to the fullest extent.
  2. Loosen the small vent screw a few turns on the fuel filter.
  3. Operate the fuel pump until bubble-free fuel flows; tighten vent screw.
  4. Loosen line connection (bleed point) at injection pump inlet.
  5. Operate fuel pump until bubble-free fuel flows; tighten connection.

Full service-parts list: Kubota D905BG-2 engine →, Kubota V1305BG-2 engine →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.