Kohler — Battery Charging
Maintenance
From a Kohler service manual covering: K141, K161, K181, K241, K301, K321, K341, K532, K582, K91, KT17, Kt19. Check it applies to your exact model before use.
Applies to: Kohler Kt19
Before you start
- Dangerous acid and explosive gases
- Turn ignition switch OFF or disconnect battery cables before charging to prevent ignition coil overheating and explosion
- Do not allow baking soda solution to enter the battery cells
Procedure
- Charge the battery only in a well-ventilated area away from sparks and flames.
- When disconnecting battery cables, always disconnect the negative (-) cable first.
- When connecting battery cables, always connect the negative cable last.
- Check electrolyte level regularly; add distilled water to maintain it.
- Clean cables, terminals and external surfaces with a baking soda and water solution, then rinse.
Specs & values
- Battery should be a 12 volt unit rated at 32 amp hours minimum
- Replace/charge if voltage drops below 9 while cranking
Full service-parts list: Kohler Kt19 →
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.