Procedure
- Disconnect the high tension leads from spark plugs so the engine will not start.
- Remove the air cleaner cover, element and base.
- Push the start switch on the controller to the start position and hold for five seconds.
- The choke should fully close and release when the start switch is released.
- If the choke does not function properly, see the Service Guide.
Full service-parts list: Kohler Kt19 →