Home›Repair guides›Kohler›Natural Gas Fuel Conversion Procedure

Kohler 2000ROZD — Natural Gas Fuel Conversion Procedure

Adjustments · Fuel regulator

For the Kohler 2000ROZD, from the Kohler operator's manual.

Applies to: Kohler 2000ROZD

Before you start

  • Lower-than-specified pressures may result in poor response to load changes or lack of power.

Procedure

  1. Remove the fuel regulator cover plug.
  2. Replace the spring and adjustment screw.
  3. Connect a manometer to check fuel supply pressure on the carburetor side of the regulator, downstream of accessories.
  4. With the generator set running at full load, rotate the adjustment screw until manometer pressure matches the specified pressure.
  5. Reinstall the cover plug.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Use the lower pressure value if the generator set still provides good response and full power.

Full service-parts list: Kohler 2000ROZD →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.