Home›Repair guides›Kohler›Emergency Stop Switch Resetting Procedure

Kohler 2000ROZD — Emergency Stop Switch Resetting Procedure

Operation · Emergency stop switch and air damper

For the Kohler 2000ROZD, from the Kohler operator's manual.

Applies to: Kohler 2000ROZD

Before you start

  • The generator set does not crank until the resetting procedure is completed.

Procedure

  1. Investigate the cause of the emergency stop and correct the circuit or wiring problem(s).
  2. If the remote emergency stop switch was activated, reset it by replacing the glass piece. If the controller-mounted switch was activated, rotate it clockwise until it springs back.
  3. If the controller air damper lamp is lit, reset the engine air damper by rotating the air damper lever until the light goes out.
  4. Toggle the generator set master switch to OFF/RESET and then to RUN or AUTO to restart the generator set.

Tools required

  • Replacement glass piece Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler 2000ROZD →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.