Home›Repair guides›Kohler›Fuel Conversion, 14RES/RESL (NG to LP)

Kohler 14RES / 20RES — Fuel Conversion, 14RES/RESL (NG to LP)

Adjustments · Fuel system

For the Kohler 14RES / 20RES, from the Kohler service manual.

Applies to: Kohler 14RES, Kohler 20RES

Before you start

  • Explosive fuel vapors.
  • Accidental starting.

Procedure

  1. Press OFF and remove F3 fuse; disconnect battery charger.
  2. Disconnect starting battery, negative lead first; turn off fuel supply.
  3. Remove hose clamp and fuel hose from fuel block fitting.
  4. Remove hose fitting from natural gas outlet port.
  5. Remove plug from LP port.
  6. Clean plug, apply fresh pipe sealant, install in natural gas port.
  7. Clean hose fitting, apply fresh pipe sealant, install in LP port.
  8. Slide hose onto fitting and secure with clamp.
  9. Disconnect DSAI leads for LP near fuel solenoid valve.
  10. Connect and turn on new fuel supply.
  11. Reconnect battery, negative lead last; reconnect battery charger.
  12. Install F3 fuse and start generator set with RUN button.
  13. Check for leaks using a gas leak detector.
  14. Run generator set and check operation; adjust output and stability if necessary.
  15. Press OFF to shut down generator set.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Do not adjust factory-sealed fuel metering valves.

Full service-parts list: Kohler 14RES →, Kohler 20RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →