Home›Repair guides›Kohler›Frequency Adjustment, RDC Controller

Kohler 14RES / 20RES — Frequency Adjustment, RDC Controller

Adjustments · Engine governor

For the Kohler 14RES / 20RES, from the Kohler service manual.

Applies to: Kohler 14RES, Kohler 20RES

Before you start

  • Hazardous voltage.
  • Moving parts.

Procedure

  1. Attach frequency meter to AC output leads or load-side outlet.
  2. Start and run generator at least 10 minutes to normal operating temperature.
  3. Adjust engine governor speed (parameter 4P) to 60 Hz or 50 Hz as appropriate.
  4. With no load, adjust governor gain (parameter 5P) until stable with no hunting or surging.
  5. Check frequency; repeat steps 3 and 4 if necessary.
  6. Save settings.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 4P=50: 3600 rpm at 60 Hz or 3000 rpm at 50 Hz.
  • 4P=00: 3420 rpm at 60 Hz or 2850 rpm at 50 Hz.
  • 4P=99: 3776 rpm at 60 Hz or 3150 rpm at 50 Hz.

Full service-parts list: Kohler 14RES →, Kohler 20RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.