Home›Repair guides›Generac›Using a Booster Battery or Charger

Generac — Using a Booster Battery or Charger

Operation

From a Generac owner's manual covering: MDG150, MDG175, MDG250. Check it applies to your exact model before use.

Applies to: Generac MDG150, Generac MDG175, Generac MDG250, John Deere 6068HFG05 / 6068HFG06 engine

Before you start

  • Explosion. Batteries emit explosive gases while charging. Keep fire and spark away.
  • Equipment damage. Do not make battery connections in reverse.

Procedure

  1. Connect booster battery or batteries to produce the required system current.
  2. Connect one end of jumper cable to the POSITIVE (+) post of the booster battery.
  3. Connect the other end of the jumper cable to the POSITIVE (+) post of battery connected to starter.
  4. Connect one end of the other jumper cable to the NEGATIVE (-) post of the booster battery.
  5. Make the last connection of the NEGATIVE (-) cable to a good ground on the engine frame away from the batteries.
  6. Start the engine; disconnect jumper cables immediately after engine starts, NEGATIVE (-) cable first.

Tools required

  • Heavy-duty jumper cables Amazon
  • 12 volt booster battery Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Parallel: Amps = twice as a single battery; Volts = same as single battery

Full service-parts list: Generac MDG150 →, Generac MDG175 →, Generac MDG250 →, John Deere 6068HFG05 / 6068HFG06 engine →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.