Home›Repair guides›Generac›Test 6 – Check Capacitor

Generac — Test 6 – Check Capacitor

Testing & diagnosis · Excitation capacitor

From a Generac service manual covering: GP1800, GP1850, GP3250, GP5000, GP5500, GP6500, GP7000, GP8000. Check it applies to your exact model before use.

Applies to: Generac GP1800, Generac GP3250, Generac GP5000, Generac GP5500, Generac GP6500, Generac GP7000, Generac GP8000, Generac OHVI engine

Before you start

  • The capacitor may need to be discharged before testing. Use proper protective equipment with an exploded capacitor.

Procedure

  1. Consult meter owner's manual for measuring capacitance.
  2. Connect meter leads directly across the capacitor terminals.
  3. Read the µf; should display the rated value ± 5µf.
  4. Replace capacitor if any other reading is displayed.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • ± 5 µf tolerance
  • Configuration A 47µf (440 VAC); Configuration B 28µf

Full service-parts list: Generac GP1800 →, Generac GP3250 →, Generac GP5000 →, Generac GP5500 →, Generac GP6500 →, Generac GP7000 →, Generac GP8000 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.