Procedure

  1. Loosen the governor clamp bolt.
  2. Hold governor lever at wide open throttle; rotate governor shaft clockwise fully.
  3. Tighten governor lever clamp bolt to 70 inch-pounds (8 Nm).
  4. Start generator; let it stabilize and warm up at no-load.
  5. Connect frequency meter across generator AC output leads.
  6. Turn the primary adjust screw to obtain a frequency of 62.5 Hz.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 70 inch-pounds (8 Nm) clamp bolt torque
  • 62.5 Hz no-load frequency

Full service-parts list: Generac GP1800 →, Generac GP3250 →, Generac GP5000 →, Generac GP5500 →, Generac GP6500 →, Generac GP7000 →, Generac GP8000 →