Home›Repair guides›Generac›Test 4 – Test DC Circuit Breaker

Generac — Test 4 – Test DC Circuit Breaker

Testing & diagnosis

From a Generac service manual covering: iX 1600, iX 2000, iX 800. Check it applies to your exact model before use.

Applies to: Generac iX 1600, Generac iX 2000, Generac iX 800

Procedure

  1. Remove the electrical panel so that the DC circuit breaker is exposed and remove both wires from the breaker.
  2. Ensure that the breaker is reset and not tripped.
  3. Set VOM to measure resistance.
  4. Connect meter leads across the breaker and measure resistance. CONTINUITY should be measured.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • CONTINUITY

Full service-parts list: Generac iX 1600 →, Generac iX 2000 →, Generac iX 800 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →