Procedure
- Set a voltmeter to measure resistance.
- Remove all wires from the START-RUN-STOP Switch.
- Check terminal 2 to 1: CONTINUITY in START, INFINITY in STOP.
- Check terminal 2 to 3: CONTINUITY in STOP, INFINITY in START.
- Reconnect all wires to the switch.
Tools required
- voltmeter (resistance) Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- CONTINUITY / INFINITY as listed
Full service-parts list: Generac GP1800 →, Generac GP3250 →, Generac GP5000 →, Generac GP5500 →, Generac GP6500 →, Generac GP7000 →, Generac GP8000 →
Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.