Home›Repair guides›Generac›Test 21 – Test FlexPower Switch

Generac — Test 21 – Test FlexPower Switch

Testing & diagnosis

From a Generac service manual covering: iX 1600, iX 2000, iX 800. Check it applies to your exact model before use.

Applies to: Generac iX 1600, Generac iX 2000, Generac iX 800

Procedure

  1. Disconnect the orange and brown wires from the FlexPower switch (FPS).
  2. Set VOM to measure resistance.
  3. Set FPS to 'ECO' position. Connect one meter test lead to Pin 1 and the other to Pin 2. Measure resistance and record.
  4. Set FPS to 'HIGH' position. Repeat Step 4. Measure resistance and record.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • ECO: INFINITY
  • HIGH: CONTINUITY

Full service-parts list: Generac iX 1600 →, Generac iX 2000 →, Generac iX 800 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →