Home›Repair guides›Generac›Test 20 - Check Spark Plugs / Test 23 - Check Valve Adjustment

Generac — Test 20 - Check Spark Plugs / Test 23 - Check Valve Adjustment

Adjustments · engine valvetrain

From a Generac service manual covering: GP1000, GP1100, GP1800, GP2000, GP2200, GP2600, GP2800, GP3250, GP3300, GP3600, GP5000, GP5500…. Check it applies to your exact model before use.

Applies to: Generac GP1800, Generac GP3250, Generac GP3300, Generac GP5000

Procedure

  1. Adjust valve clearance with engine at room temperature
  2. Position piston at TDC of compression stroke (both valves closed), or set intake/exhaust valve fully open method
  3. Loosen rocker arm jam nut; turn pivot ball stud while checking clearance with a feeler gauge
  4. When clearance is correct, hold pivot ball stud and tighten rocker arm jam nut to specified torque with a crow foot wrench
  5. Recheck valve clearance to make sure it did not change
  6. Install rocker arm cover with a new gasket

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • see valve clearance and rocker arm jam nut torque tables

Full service-parts list: Generac GP1800 →, Generac GP3250 →, Generac GP3300 →, Generac GP5000 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.