Home›Repair guides›Generac›Test 16 – Test Fuel Shutoff Switch

Generac — Test 16 – Test Fuel Shutoff Switch

Testing & diagnosis

From a Generac service manual covering: iX 1600, iX 2000, iX 800. Check it applies to your exact model before use.

Applies to: Generac iX 1600, Generac iX 2000, Generac iX 800

Procedure

  1. Open up the electrical panel so that the control panel wiring is exposed.
  2. Set fuel shutoff valve to the CLOSED position.
  3. Disconnect the J1 connector from the LED module.
  4. Set VOM to measure resistance.
  5. Connect one meter test lead to J1 Pin 6 and the other to ground. Measure and record.
  6. Set fuel shutoff valve to the OPEN position and repeat Step 5.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • CLOSED: OPEN (INFINITY)
  • OPEN: CLOSED (CONTINUITY)

Full service-parts list: Generac iX 1600 →, Generac iX 2000 →, Generac iX 800 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.