Home›Repair guides›Generac›Test 14 – Test Ignition Trigger Assembly

Generac — Test 14 – Test Ignition Trigger Assembly

Testing & diagnosis

From a Generac service manual covering: iX 1600, iX 2000, iX 800. Check it applies to your exact model before use.

Applies to: Generac iX 1600, Generac iX 2000, Generac iX 800

Procedure

  1. Remove the electrical panel so that the LED module is exposed and disconnect the J1 connector.
  2. Set VOM to measure resistance.
  3. Locate Pin 3 on the J1 connector. Connect one meter test lead to Pin 3 and the other to engine ground. Measure and record the resistance.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • iX800: 30 Ohms ± 5 Ohms
  • iX1600: 30 Ohms ± 5 Ohms
  • iX2000 FridayParts $39.32: 129 Ohms ± 5 Ohms

Full service-parts list: Generac iX 1600 →, Generac iX 2000 →, Generac iX 800 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.