Generac — Removing Battery
Maintenance
From a Generac owner's manual covering: XG03245, XG04045, XG04845. Check it applies to your exact model before use.
Applies to: Generac Model, Generac Number, Generac XG03245, Generac XG04045, Generac XG04845
Before you start
- Electrical shock. Disconnect battery ground terminal before working on battery or battery wires. Failure to do so could result in death or serious injury. (W000164)
Procedure
- Remove negative battery cable from negative terminal.
- Remove positive battery cable from positive terminal.
- Install rubber protective cover over positive terminal.
- Release buckle on nylon strap securing battery.
- Grasp battery strap and lift battery from tray.
- Remove rubber protective cover from positive terminal.
Full service-parts list: Generac Model →, Generac Number →, Generac XG03245 →, Generac XG04045 →, Generac XG04845 →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.