Generac QuietPact 40 — Removal From Service (Storage)

Maintenance · Generator

For the Generac QuietPact 40, from the Generac owner's manual.

Applies to: Generac QuietPact 40, Generac GN-220 engine

Before you start

  • Never store the battery on any concrete or earthen floor.

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.
  3. While the engine is still warm, drain the oil completely; refill crankcase with SAE 10W-30 API SF oil.
  4. Attach a tag to the engine indicating viscosity and classification of oil in the crankcase.
  5. Remove spark plug and pour two or three tablespoons clean engine oil into the spark plug opening; reinstall and tighten.
  6. Remove battery and store in a cool, dry room on a wooden board.
  7. Clean and wipe the entire generator.

Specs & values

  • Use out-of-service procedure if unit will be out of service longer than 30 days

Full service-parts list: Generac QuietPact 40 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.