Generac QuietPact 40 — Removal From Service (Storage)
Maintenance · Generator
For the Generac QuietPact 40, from the Generac owner's manual.
Applies to: Generac QuietPact 40, Generac GN-220 engine
Before you start
- Never store the battery on any concrete or earthen floor.
Procedure
- Start the engine and let it warm up.
- Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.
- While the engine is still warm, drain the oil completely; refill crankcase with SAE 10W-30 API SF oil.
- Attach a tag to the engine indicating viscosity and classification of oil in the crankcase.
- Remove spark plug and pour two or three tablespoons clean engine oil into the spark plug opening; reinstall and tighten.
- Remove battery and store in a cool, dry room on a wooden board.
- Clean and wipe the entire generator.
Specs & values
- Use out-of-service procedure if unit will be out of service longer than 30 days
Full service-parts list: Generac QuietPact 40 →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.