Generac Q-70G — Starting the Generator

Operation · Generator control panel

For the Generac Q-70G, from the Generac owner's manual.

Applies to: Generac GN-480 engine

Before you start

  • If the engine does not start after cranking for 15 seconds, release the Start/Stop switch and try again. Holding the switch longer than 15 seconds can damage the starter motor.

Procedure

  1. Turn OFF electrical loads using the means provided in your vehicle (such as a main line circuit breaker or transfer switch).
  2. If not started in more than two weeks, press the Fuel Pump Primer switch for about five seconds. Skip if engine is warm.
  3. Hold the engine Start/Stop switch in the START position to crank the engine; release when the engine starts.
  4. Let the engine run at no-load for a few minutes to stabilize and warm up.
  5. Turn ON electrical loads using the means provided.

Specs & values

  • Do not crank longer than 15 seconds
  • Run at no-load a few minutes before applying loads

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.