Generac PRIMEPACT 50 / PrimePact 50 LP — Removal from Service (Storage)

Maintenance · Generator

For the Generac PRIMEPACT 50 / PrimePact 50 LP, from the Generac owner's manual.

Applies to: Generac GN-410 engine

Before you start

  • Never store the battery on any concrete or earthen floor.

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.
  3. While the engine is warm, drain the oil completely and refill crankcase with SAE 10W-30 API SF oil.
  4. Attach a tag to the engine indicating the viscosity and classification of the oil.
  5. Remove spark plug, pour two or three tablespoons of clean engine oil into opening, reinstall plug.
  6. Remove the battery and store it in a cool, dry room on a wooden board.
  7. Clean and wipe the entire generator.

Specs & values

  • Out of service longer than 30 days

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.