Home›Repair guides›Generac›Cleaning the Foam Precleaner

Generac PRIMEPACT 50 / PrimePact 50 LP — Cleaning the Foam Precleaner

Maintenance · Engine air cleaner

For the Generac PRIMEPACT 50 / PrimePact 50 LP, from the Generac owner's manual.

Applies to: Generac GN-410 engine

Procedure

  1. Turn the two screws counterclockwise to loosen.
  2. Remove the cover, foam precleaner and paper filter.
  3. Remove the foam precleaner from the cover.
  4. Wash the foam precleaner in liquid detergent and water.
  5. Wrap the precleaner in a clean cloth and gently squeeze it dry.
  6. Saturate the precleaner in clean engine oil and squeeze out excess (do not twist).
  7. Install the precleaner into the cover, followed by the paper filter.
  8. Install the cover and tighten the two screws.

Specs & values

  • Every three months or every 25 hours of operation

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.