For the Generac PowerPact 5.6 kVA 50 Hz, from the Generac service manual.

Applies to: Generac PowerPact 5.6 kVA 50 Hz

Procedure

  1. Ensure the engine is cool before checking.
  2. Remove spark plug wire and position it away from the plug.
  3. Remove the spark plug.
  4. Rotate the engine clockwise until piston is at TDC compression stroke.
  5. Remove the four screws attaching the valve cover.
  6. Loosen rocker jam nut; set clearance with a feeler gauge.
  7. CorePower: intake 0.005-0.007 in; exhaust 0.007-0.009 in.
  8. PowerPact: intake and exhaust 0.002-0.004 in.
  9. Tighten jam nut to 70 to 106 in-lbs; recheck clearance; install new gasket.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • CorePower intake 0.005-0.007 in (0.13-0.17 mm)
  • CorePower exhaust 0.007-0.009 in (0.18-0.22 mm)
  • PowerPact intake and exhaust 0.002-0.004 in (0.05-0.1 mm)
  • Rocker arm jam nut 70 to 106 in-lbs