Generac OHV GA-420 Engine

The Generac OHV GA-420 is a 0.42 L engine rated at 3600 rpm. It powers generator sets from Generac, including the PowerPact 5.6 kVA 50 Hz. It holds 1.1 L (0.3 gal) of oil.

Also known as: OHV GA-420, Generac OHV GA-420

0.42 L
Displacement
3600 rpm
Rated speed
1.1 L
Oil capacity

Engine specifications

Oil capacity1.1 L
Displacement0.42 L
Rated speed3600 rpm

Common problems

15
  • Voltage and frequency drop excessively when loads are applied
    Cause: Overload condition; shorted condition in a connected load or in one of the load circuits; stator AC power windings faulty; engine condition poor
    Fix: Reduce loads to unit's rated capacity; look for a shorted condition in a connected load or in one of the load circuits and repair or replace; check stator AC power windings; go to Problem 23 – Engine Starts Hard and Runs Rough/Lacks Power
  • Generator produces zero voltage or residual voltage
    Cause: Main circuit breaker set to OFF or open, or has failed; fuses blown; brushes and slip rings faulty; rotor and rotor circuit resistance incorrect; stator faulty; voltage regulator faulty
    Fix: Reset breaker to ON or replace if bad; repair or replace fuses; check brushes and slip rings; perform resistance check of rotor and rotor circuit; test stator; replace voltage regulator; replace rotor only; replace stator only; replace rotor and stator
  • Generator produces low voltage at no-load
    Cause: Voltage regulator adjustment incorrect; engine governor adjustment incorrect; rotor and rotor circuit resistance incorrect; stator faulty
    Fix: Adjust voltage regulator; adjust engine governor; perform resistance check of rotor and rotor circuit; test stator; replace rotor only; replace rotor and stator
  • Generator produces high voltage at no-load
    Cause: Voltage regulator adjustment incorrect; engine governor adjustment incorrect; defective voltage regulator
    Fix: Adjust voltage regulator; check and adjust engine governor; replace defective voltage regulator
  • Blown T1 fuse T1
  • Unit Starts and Transfer Occurs When Utility Power Is On Problem 14
    Fix: Test 41 – Check Utility Sensing Voltage at Controller; Test 38 – Check N1 & N2 Voltage; Test 39 – Check Utility Sense Voltage; Test 32 – Check Fuse F1 & F2; replace controller; correct utility source voltage; replace; go to Problem 7; repair or replace wiring; repair or replace wire N1A/N2A between N1/N2 lugs and fuse holder; repair N1/N2 open wiring between transfer switch and generator; check meter settings and functionality
  • Shutdown Alarm/Fault Occurred — Overspeed Problem 24
    Fix: Test 13 – Check and Adjust Engine Governor; repair linkage if binding; check throttle operation
  • Shutdown Alarm/Fault Occurred — Overcrank Problem 24
    Fix: Test 64 – Check for Ignition Spark; Test 67 – Check Ignition Magneto; Test 79 – Check Shutdown Wire; repair or replace shorted wire 18 or controller; refer to engine service manual
  • Shutdown Alarm/Fault Occurred — No RPM Sense Problem 24
    Fix: Test 71 – Check Wire 18 Continuity; Test 12 – Check AC Output Frequency; repair or replace; proceed to Problem 22; proceed to Problem 27
  • Shutdown Alarm/Fault Occurred — Low Oil PowerPact Problem 24
    Fix: Test 68B – Check Oil Level Switch and Wire 86
  • Shutdown Alarm/Fault Occurred — Low Oil CorePower Problem 24
    Fix: Test 68A – Check Oil Pressure Switch and Wire 86
  • Shutdown Alarm/Fault Occurred — Low Battery Problem 24
    Fix: Go to Problem 21
  • Shutdown Alarm/Fault Occurred — High Temp Problem 24
    Fix: Test 69 – Check High Oil Temperature Switch; check installation for proper airflow or replace defective switch
  • No Battery Charge — no battery supply voltage Problem 27
    Fix: Test 74 – Check Battery Charger Supply Voltage; Test 75 – Check Battery Charger Output Voltage; Test 78 – Check Wire 0/15B; repair or replace; replace charger
  • Load Management Module (SMM) LED is ON, Load Not Powered SMM Problem 2
    Cause: Generator was overloaded, shed occurred and power applied to SMM; this will also occur if utility power was just applied (except if transferring from gen to utility)
    Fix: Test 37 – Check Voltage at Contactor

Compiled from service & troubleshooting documentation across every generator set that uses the Generac OHV GA-420.

Service intervals

18
ItemActionHoursMonthsNotes
Oil levelCheck24 hrCorePower; monthly or 24 hours of continuous operation
Air cleanerClean50 hr3 moPowerPact; 3 months or 50 hours
OilChange100 hr12 moFirst service — PowerPact; change after first 20 hours or 1 month, then 100 hours or 6 months
Oil filterChange100 hr12 moFirst service — CorePower; change after first 8 hours, then every 100 hours or 1 year
Spark plugInspect100 hr6 moPowerPact; 6 months or 100 hours
Complete tune-upOther200 hr12 moCorePower; to be completed by a dealer
Spark plugReplace200 hr12 moCorePower; 1 year or 200 hours
Air cleanerReplace300 hr12 moPowerPact; 1 year or 300 hours
Spark plugChange300 hr12 moPowerPact; 1 year or 300 hours
Valve clearanceCheck300 hr12 moFirst service — PowerPact; check after first 20 hours, then every 300 hours or 1 year
Battery - remove corrosion, ensure drynessClean12 moPowerPact; yearly
Battery charge stateCheck12 moPowerPact; yearly
Battery electrolyte levelCheck6 moCorePower; every 6 months
Battery electrolyte level (unsealed batteries only)Check6 moPowerPact; every 6 months
Battery terminals - clean and tightenClean12 moPowerPact; yearly
Fuel lines and connectionsInspect1 moCorePower; monthly
Vibration, Noise, LeakageInspect1 moPowerPact; monthly
Vibration, Noise, Leakage, TemperatureInspect1 moCorePower; monthly

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
GapSpark plug gap0.76 mm (0.030 inch)mm
PressureCylinder leak down tester regulated pressure80PSI90 PSI air source
PressureFuel pressure - LP gas - inlet side of fuel solenoid10-12inches water column
PressureFuel pressure - natural gas - inlet side of fuel solenoid5-7inches water column
PressureMinimum allowable compression pressure60PSIcold engine
PressureNormal oil pressure35-40psiengine running
PressureOil pressure - shut engine down immediately if below4.5psi
PressureOil pressure switch rating (single cylinder)10psi
ResistanceChoke solenoid (component table)4ohms
ResistanceChoke solenoid coil resistance~3.7ohms
ResistanceFuel solenoid FS1 nominal resistance14-16ohms
ResistanceMain fuel solenoid16ohms
ResistanceRotor resistance - CorePower40 +/-20ohms
ResistanceRotor resistance - PowerPact50 +/-20ohms
ResistanceStarter contactor8ohms
ResistanceStator DPE winding Blue (2)/Blue (6) - PowerPact1.85ohms
ResistanceStator DPE winding Blue/Blue - CorePower1.158ohms
ResistanceStator power winding 11/22 - PowerPact 50 Hz0.36ohms
ResistanceStator power winding 11/22 - PowerPact 60 Hz0.24ohms
ResistanceStator power winding 33/44 - PowerPact 50 Hz0.36ohms
ResistanceStator power winding 33/44 - PowerPact 60 Hz0.24ohms
ResistanceStator power winding Blue/Black - CorePower0.346ohms
ResistanceStator power winding White/Black - CorePower0.173ohms
ResistanceStator power winding White/Blue - CorePower0.173ohms
ResistanceStator sensing winding Green/White - CorePower0.064ohms
ResistanceStator sensing winding White (S1)/Green (S2) - PowerPact0.024ohms
ResistanceTransfer relay115ohms
SpeedNo-load speed - 50 Hz3120RPM52 Hz
SpeedNo-load speed - 60 Hz3750RPM62.5 Hz
SpeedOver speed shutdown - 50 Hz3600RPMfor three (3) seconds, or 3750 RPM immediately
SpeedOver speed shutdown - 60 Hz4320RPMfor three (3) seconds, or 4500 RPM immediately
TemperatureHigh oil temperature shutdown124 C (255 F)C
TemperatureHigh oil temperature switch - contacts close at293F
TemperatureHigh oil temperature switch test range283-305 F (139-151 C)F
Torque3/8-16 screw to mounting foot5-8ft-lbs
TorqueGovernor lever clamp bolt - CorePower70in-lbs
TorqueGovernor lever clamp bolt - CorePower8Nm
TorqueGovernor pinch bolt nut - PowerPact62in-lbs
TorqueM10 x 1.25 engine to vibration isolator15-20ft-lbs
TorqueM3 x 0.5 screw into aluminum8-10in-lbs
TorqueM3 x 0.5 taptite screw into extruded hole8-18in-lbs
TorqueM5 x 0.5 screw into aluminum25-35in-lbs
TorqueM5 x 0.8 screw on band clamp7.5-9ft-lbs
TorqueM5 x 0.8 taptite screw into extruded hole25-50in-lbs
TorqueM6 x 1.0 nyloc nut on dead front plate40-50in-lbs
TorqueM6 x 1.0 screw flange nuts - airbox to cylinder head7-8ft-lbs
TorqueM6 x 1.0 screw into aluminum50-60in-lbs
TorqueM6 x 1.0 screw on band clamp14-15ft-lbs
TorqueM6 x 1.0 taptite screw into extruded hole50-96in-lbs
TorqueM8 x 1.0 nuts - exhaust to cylinder head20-22ft-lbs
TorqueM8 x 1.25 taptite screw into extruded hole15-20ft-lbs
TorqueM8 x 1.25 vibration isolator to base20-22ft-lbs
TorqueRocker arm jam nut70 to 106in-lbs
TorqueRotor bolt - CorePower30ft-lbs
TorqueRotor bolt - PowerPact27-33ft-lbs
TorqueStator bolts - CorePower6ft-lbs
TorqueStator bolts - PowerPact72in-lbs
Valve clearanceExhaust valve - CorePower0.007-0.009 in (0.18-0.22 mm)incold
Valve clearanceExhaust valve - PowerPact0.002-0.004 in (0.05-0.1 mm)incold
Valve clearanceIntake valve - CorePower0.005-0.007 in (0.13-0.17 mm)incold

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oilSynthetic SAE 5W-30API Service Class SJ, SL or betterfor all temperature ranges; do not use synthetic until 50 hours of operation
Engine oilSAE 10W-30API Service Class SJ, SL or better-23°C to 4°Cbetween 40 and -10 F (4 and -23 C)
Engine oilSAE 30API Service Class SJ, SL or betterabove 0°Cabove 32 F (0 C); do not use special additives
FuelLP vaporat least 2,520 BTU per cubic footvapor withdrawal system only; fuel pressure must never drop below 10 inches water column
FuelNatural gasat least 1,000 BTU per cubic footfuel pressure must never drop below 5 inches water column

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Test 13 - Check and Adjust Engine Governor (CorePower) adjustment

Tools: 13 mm wrench, frequency meter

  1. Cycle throttle to confirm throttle rod and anti-lash spring move freely.
  2. Loosen the governor clamp bolt (13 mm).
  3. Hold governor lever wide open; rotate governor shaft clockwise fully.
  4. Tighten governor lever clamp bolt to 70 in-lbs (8 Nm).
  5. Connect a frequency meter across the AC output leads (MLCB).
  6. Start the generator and warm up at no-load.
  7. Turn the adjust nut to obtain a frequency reading of 62.5 Hz.
Test 70 - Check and Adjust Valves adjustment

Tools: feeler gauge, socket, wrench

  1. Ensure the engine is cool before checking.
  2. Remove spark plug wire and position it away from the plug.
  3. Remove the spark plug.
  4. Rotate the engine clockwise until piston is at TDC compression stroke.
  5. Remove the four screws attaching the valve cover.
  6. Loosen rocker jam nut; set clearance with a feeler gauge.
  7. CorePower: intake 0.005-0.007 in; exhaust 0.007-0.009 in.
  8. PowerPact: intake and exhaust 0.002-0.004 in.
  9. Tighten jam nut to 70 to 106 in-lbs; recheck clearance; install new gasket.
Check Compression diagnostic

Tools: compression gauge

  1. Remove the spark plug.
  2. Insert a compression gauge into the cylinder.
  3. Crank the engine until there is no further increase in pressure.
  4. Record the highest reading obtained.
  5. Minimum allowable compression pressure for a cold engine is 60 PSI.
Test 1 - Check Main Circuit Breaker diagnostic

Tools: Volt-Ohm-Meter

  1. Set VOM to R x 1 scale and zero the meter.
  2. With generator shut down, disconnect all wires from breaker terminals.
  3. Connect probes to Wire 11 (Blue) terminal and the E1 terminal.
  4. Set breaker Closed; VOM should read CONTINUITY.
  5. Set breaker Open; VOM should indicate INFINITY.
  6. Repeat with probes across Wire 44 (Black) and the E2 terminal.
Test 6 - Resistance Check of Rotor and Rotor Circuit diagnostic

Tools: Volt-Ohm-Meter

  1. Disconnect the Red (Wire 4) and White (Wire 1) wires from the regulator.
  2. Set a VOM to measure resistance.
  3. Measure across the brush wires and record the resistance.
  4. CorePower: approximately 40 ohms +/-20. PowerPact: approximately 50 ohms +/-20.
Reconfigure the Fuel System maintenance

Tools: needle nose pliers

  1. Locate fuel throttle assembly mounted to engine intake.
  2. Remove hose clamp and hose from throttle assembly.
  3. Remove Natural Gas (larger ID) fuel jet from fuel inlet.
  4. Obtain the Propane fuel jet (smaller ID) supplied loose.
  5. Verify the O-ring is installed in the fuel jet groove.
  6. Insert the Propane fuel jet into the end of the fuel inlet.
  7. Reinstall hose and clamp onto fuel inlet and secure.
  8. Verify the hose has not been kinked in any way.
Before Starting operation

⚠ Do not fill oil above the FULL mark.

  1. Ensure the generator is OFF.
  2. Set the generator main circuit breaker to OFF (or OPEN).
  3. Turn off all breakers that will be powered by the generator.
  4. Check crankcase oil level; fill to dipstick FULL mark.
  5. Check fuel supply; purge and leak test lines; open all fuel shutoff valves.
Generator Activation operation
  1. Locate and record the generator serial number.
  2. Contact Generac to obtain your activation code.
  3. Hold the OFF button for 3 seconds; all LEDs flash twice.
  4. Enter the 6-press code using AUTO, OFF and SET EXERCISE within 20 seconds.
  5. If incorrect, AUTO/OFF/MANUAL flash 3 times; return to Step 3.
  6. If correct, all LEDs scroll bottom to top 5 times.
Manual Start and Transfer to Standby operation

⚠ Engine will crank and start!

  1. Set the controller switch to OFF mode.
  2. Set the generator main line circuit breaker to Open.
  3. Locate a means of Utility disconnect and set it to OFF.
  4. Manually actuate the breaker to Standby in the transfer switch.
  5. Set the controller switch to MANUAL mode; engine cranks and starts.
  6. Warm up 1-2 minutes; set the generator MLCB to Closed.
Retransfer to Utility and Manual Shutdown operation
  1. Set the generator MLCB to the OPEN position.
  2. Allow the generator to run at no-load several minutes to cool down.
  3. Set the generator controller to OFF mode.
  4. Locate a means of Utility disconnect and set it to OFF.
  5. Manually actuate the breaker in the transfer switch to Utility.
  6. Restore Utility voltage to the transfer switch.
  7. Set the generator controller to AUTO mode.
Select Automatic Operation operation
  1. Ensure transfer mechanism is in the Utility position.
  2. CLOSE the Utility source main line circuit breaker.
  3. Verify Utility voltage at terminals N1 and N2.
  4. Actuate the generator main line circuit breaker to Closed.
  5. Set the generator controller to the AUTO mode.
Shut Generator Down While Under Load operation

⚠ If turning the unit off for longer than 24 hours, remove the F1 fuse from the generator controller.

  1. Turn the main utility disconnect OFF.
  2. Turn the main line circuit breaker (MLCB) on the generator to OFF (OPEN).
  3. Turn the generator OFF.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the oil capacity of the Generac OHV GA-420?

The Generac OHV GA-420 engine has an oil capacity of 1.1 liters.

What is the displacement of the Generac OHV GA-420?

The Generac OHV GA-420 has a displacement of 0.42 liters.

Which generators use the Generac OHV GA-420 engine?

The Generac OHV GA-420 powers 1 generator set(s), including Generac PowerPact 5.6 kVA 50 Hz.

What is a common problem with the Generac OHV GA-420 engine?

A commonly reported issue on generators using the Generac OHV GA-420 is: Voltage and frequency drop excessively when loads are applied. Cause: Overload condition; shorted condition in a connected load or in one of the load circuits; stator AC power windings faulty; engine condition poor. Fix: Reduce loads to unit's rated capacity; look for a shorted condition in a connected load or in one of the load circuits and repair or replace; check stator AC power windings; go to Problem 23 – Engine Starts Hard and Runs Rough/Lacks Power.