Home›Repair guides›Generac›Test 6 - Resistance Check of Rotor and Rotor Circuit

Generac PowerPact 5.6 kVA 50 Hz — Test 6 - Resistance Check of Rotor and Rotor Circuit

Testing & diagnosis · Rotor and brush assembly

For the Generac PowerPact 5.6 kVA 50 Hz, from the Generac service manual.

Applies to: Generac PowerPact 5.6 kVA 50 Hz

Procedure

  1. Disconnect the Red (Wire 4) and White (Wire 1) wires from the regulator.
  2. Set a VOM to measure resistance.
  3. Measure across the brush wires and record the resistance.
  4. CorePower: approximately 40 ohms +/-20. PowerPact: approximately 50 ohms +/-20.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Rotor resistance CorePower 40 ohms +/-20
  • Rotor resistance PowerPact 50 ohms +/-20

Full service-parts list: Generac PowerPact 5.6 kVA 50 Hz →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →