Home›Repair guides›Generac›Check Compression

Generac PowerPact 5.6 kVA 50 Hz — Check Compression

Testing & diagnosis · Engine cylinder

For the Generac PowerPact 5.6 kVA 50 Hz, from the Generac service manual.

Applies to: Generac PowerPact 5.6 kVA 50 Hz

Procedure

  1. Remove the spark plug.
  2. Insert a compression gauge into the cylinder.
  3. Crank the engine until there is no further increase in pressure.
  4. Record the highest reading obtained.
  5. Minimum allowable compression pressure for a cold engine is 60 PSI.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Minimum compression 60 PSI cold

Full service-parts list: Generac PowerPact 5.6 kVA 50 Hz →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.