For the Generac NP-50G, from the Generac owner's manual.

Applies to: Generac NP-50G, Generac GN-410 engine

Before you start

  • Never store battery on concrete or earth floors

Procedure

  1. Start the engine and let it warm up.
  2. Close fuel shutoff valve in fuel supply line and let engine run out of fuel.
  3. While engine is still warm, drain oil completely and refill crankcase with SAE 10W30 oil, API SF.
  4. Attach tag to engine indicating oil viscosity and classification.
  5. Remove spark plug and pour two or three tablespoons clean engine oil into opening.
  6. Crank engine several times to distribute oil, then install and tighten spark plug.
  7. Remove battery and store in a cool, dry room on a wooden board.
  8. Clean and wipe the entire generator.

Specs & values

Full service-parts list: Generac NP-50G →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.