Generac MMG50ITM — Checking Generator Drive Plate Torque

Maintenance

For the Generac MMG50ITM, from the Generac operator's manual.

Applies to: Generac MMG50ITM, Isuzu 4LE2XAGV01 engine

Procedure

  1. Disconnect the engine starting battery.
  2. Remove the generator fan guard.
  3. Torque each of the drive plate bolts to 36 ft-lbs (49 Nm).
  4. Reinstall the generator fan guard. Reconnect the battery.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 36 ft-lbs (49 Nm)

Full service-parts list: Generac MMG50ITM →, Isuzu 4LE2XAGV01 engine →

Source: Generac operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.