Generac MMG50ITM — Auto (Remote) Starting of the Unit

Operation · Generator

For the Generac MMG50ITM, from the Generac operator's manual.

Applies to: Generac MMG50ITM, Isuzu 4LE2XAGV01 engine

Before you start

  • Verify that the contacts on any remote switch linked to the unit are OPEN before entering Auto mode.

Procedure

  1. Perform a manual start of the generator at least once to verify the engine operates correctly.
  2. To check the remote start circuit, remove the remote start terminal block wires, press Auto, and attach a jumper wire (minimum 16 gauge) across the two terminals.
  3. The engine should crank, start and run.
  4. Remove the jumper wire; the engine stops. Reconnect any necessary remote start switch wires.
  5. Confirm the unit is in Auto mode; the LCD window should have AUT highlighted.
  6. Close the main circuit breaker (set to ON (I) position).
  7. Secure the generator by closing and locking all access doors.