Home›Repair guides›Generac›Long-Term Storage Preparation

Generac iX 800 — Long-Term Storage Preparation

Maintenance · engine/fuel system

For the Generac iX 800, from the Generac operator's manual.

Applies to: Generac iX 800

Before you start

  • Do not store gasoline from one season to another

Procedure

  1. Remove all gasoline from fuel tank
  2. Run engine until it stops from lack of fuel or drain carburetor bowl via valve
  3. While engine is still warm, drain oil from crankcase and refill with recommended grade
  4. Remove spark plugs and pour about 1/2 ounce (15 ml) of engine oil into cylinders; cover spark plug hole with rag; pull starting rope several times
  5. Install and tighten spark plug
  6. Clean generator outer surfaces; check cooling air slots are open and unobstructed
  7. Store unit in a clean, dry place

Full service-parts list: Generac iX 800 →

Source: Generac operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.