Generac iX 800 — Long-Term Storage Preparation
Maintenance · engine/fuel system
For the Generac iX 800, from the Generac operator's manual.
Applies to: Generac iX 800
Before you start
- Do not store gasoline from one season to another
Procedure
- Remove all gasoline from fuel tank
- Run engine until it stops from lack of fuel or drain carburetor bowl via valve
- While engine is still warm, drain oil from crankcase and refill with recommended grade
- Remove spark plugs and pour about 1/2 ounce (15 ml) of engine oil into cylinders; cover spark plug hole with rag; pull starting rope several times
- Install and tighten spark plug
- Clean generator outer surfaces; check cooling air slots are open and unobstructed
- Store unit in a clean, dry place
Full service-parts list: Generac iX 800 →
Source: Generac operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.