Procedure

  1. Clean and inspect the mounting surfaces of the intake manifold and the cylinder head; both must be clean and flat.
  2. Clean and lightly oil the manifold bolt/stud threads.
  3. Install a new lower intake manifold gasket.
  4. Position the lower intake manifold to the cylinder head.
  5. Install retaining bolts/studs finger tight.
  6. Tighten all bolts/studs to specifications in the tightening sequence shown.
  7. First pass = 7-10 N-m (5-7 lb-ft).
  8. Final pass = 26-38 N-m (19-28 lb-ft).

Specs & values

  • First pass 7-10 N-m (5-7 lb-ft)
  • Final pass 26-38 N-m (19-28 lb-ft)

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.