Generac In-line Engine

The Generac In-line is a 1.5 L 4-cylinder naturally aspirated engine rated at 3600 rpm, producing up to 46.23 kW. It powers generator sets from Generac, including the In Line, QT022, QT027 and QT030. It holds 3.8 L (1.0 gal) of oil and 7.6 L (2.0 gal) of coolant.

Also known as: Generac In-line

1.5 L
Displacement
4
Cylinders
3600 rpm
Rated speed
46 kW
Gross power

Engine specifications

Oil capacity3.8 L
Coolant capacity7.6 L
Displacement1.5 L
Cylinders4
AspirationNaturally Aspirated
Rated speed3600 rpm
Gross power46 kW

Common problems

15
  • Warning active. SERVICE SCHEDULE C
    Fix: Perform SERVICE SCHEDULE C maintenance; press ENTER to clear.
  • Warning active. SERVICE SCHEDULE B
    Fix: Perform SERVICE SCHEDULE B maintenance; press ENTER to clear.
  • Warning active. SERVICE SCHEDULE A
    Fix: Perform SERVICE SCHEDULE A maintenance; press ENTER to clear.
  • Warning active. LOW BATTERY
    Fix: Clear alarm. From the MAIN menu on the control panel, navigate to the BATTERY MENU. Contact servicing dealer if battery is GOOD. Replace battery If CHECK BATTERY is displayed.
  • Warning active. CHARGER WARNING
    Fix: Contact servicing dealer.
  • Warning active. BATTERY PROBLEM
    Fix: Contact servicing dealer.
  • Unit will not start in AUTO with utility loss. UNDERVOLTAGE
    Fix: Contact servicing dealer.
  • Unit will not start in AUTO with utility loss. UNDERSPEED
    Fix: Contact servicing dealer.
  • Unit will not start in AUTO with utility loss. RPM SENSE LOSS
    Fix: Clear alarm. From the MAIN menu on the control panel, navigate to the BATTERY MENU. Contact servicing dealer if battery is GOOD. Replace battery If CHECK BATTERY is displayed.
  • Unit will not start in AUTO with utility loss. OVERVOLTAGE
    Fix: Contact servicing dealer.
  • Unit will not start in AUTO with utility loss. OVERSPEED
    Fix: Contact servicing dealer.
  • Unit will not start in AUTO with utility loss. OVERCRANK
    Fix: Clear alarm. Attempt to start the unit in MANUAL. If it does not start or starts and runs rough, contact servicing dealer.
  • Unit will not start in AUTO with utility loss. NOT ACTIVATED
    Fix: Refer to activation section in Owner’s Manual.
  • Unit will not start in AUTO with utility loss. MISWIRE
    Fix: Contact servicing dealer.
  • Unit will not start in AUTO with utility loss. LOW OIL PRESSURE
    Fix: Check oil level. Add oil per Owner’s Manual. Contact servicing dealer if oil level is correct.

Compiled from service & troubleshooting documentation across every generator set that uses the Generac In-line.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter059402500 hr Amazon $16.95 eBay $32.00
Fuel filterSecondary Fuel Regulator240 hr
Oil filter0G02070100100 hr Amazon $9.50 eBay KuduParts $13.00
BatteryRecommended BatteryG058665240 hr Amazon eBay
Belt0G0823 Amazon eBay $17.99
Coolant
Oil6.0 qt500 hr
Spark plugclean/re-gap spark plugs or replace as necessary250 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

6
ItemActionHoursMonthsNotes
Replace fuel filterReplace500 hr
Replace oil and filterChange500 hr
Drain/flush coolant systemDrain1000 hr
Check coolant level and hosesCheckFirst service
Check fuel levelCheckFirst service
Check oil levelCheckFirst service

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

9
TypeItemValueUnitCondition
OtherTotal Harmonic Distortion<5%
PressureLP fuel pressure7-14in Water Columnfuel system
PressureNG fuel pressure3.5-14in Water Columnfuel system
SpeedFrequency regulation (steady state)0.25%isochronous operation
SpeedSteady State Regulation (Governor)±0.25%
TemperatureOperating temperature rise above ambient120°Cabove 40°C ambient
TorqueOperating temperature rise120°C above 40°C ambientrated output
VoltageVoltage Regulation±1%
VoltageVoltage regulation1%steady state

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantEthylene glycol 50/50 mix11.0 lRG048: 11 l, RG060/RG080: 17 l
CoolantPeak Fleet-Charge 50/50 ethylene glycol-20°C to 48°C2.8 galUse demineralized or distilled water base
Engine oil15W-40API Service Class CD or better-20°C to 48°CSynthetic oil can be used in appropriate weight
FuelUltra Low Sulfur Dieselbelow 40°CMechanical engine-driven pump, 5 micron filter (15/20/30 kW), 10 micron filter (48/50 kW)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

6
CodeNameMeaningSeverityAction
HIGH TEMPERATUREHigh TemperatureEngine coolant temperature exceeds limitShutdown
LOW OIL PRESSURELow Oil PressureOil pressure below acceptable levelWarning
NOT ACTIVATEDNot ActivatedUnit will not start in AUTO with utility lossInfo
OVERCRANKOvercrankEngine overcrank faultWarning
OVERLOADOverloadUnit overloaded, shuts down during operationShutdown
RPM SENSE LOSSRPM Sense LossLoss of engine RPM signalShutdown

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
120/20836 wire3-Phase 6 wire alternator outputPower factor 0.8
120/2083Three phaseRD015, RD020, RD030, RD050
120/24014 wire1-Phase 4 wire alternator outputPower factor 1.0
120/2401Single phaseRD015, RD020, RD030, RD048
120/24036 wire3-Phase 6 wire alternator outputPower factor 0.8
120/2403Three phaseRD015, RD020, RD030, RD048, RD050
277/48036 wire3-Phase 6 wire alternator outputPower factor 0.8
277/4803Three phaseRD030, RD048, RD050

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the oil capacity of the Generac In-line?

The Generac In-line engine has an oil capacity of 3.8 liters.

What is the displacement of the Generac In-line?

The Generac In-line has a displacement of 1.5 liters with 4 cylinders.

Which generators use the Generac In-line engine?

The Generac In-line powers 26 generator set(s), including Generac In Line, Generac QT022, Generac QT027, Generac QT030, Generac QT036.

How often should you change the oil in the Generac In-line?

The Generac In-line oil change interval is every 500 hours.

What is a common problem with the Generac In-line engine?

A commonly reported issue on generators using the Generac In-line is: Warning active. SERVICE SCHEDULE C. Fix: Perform SERVICE SCHEDULE C maintenance; press ENTER to clear..