Before you start

  • Voltage selection installer code required.

Procedure

  1. Assemble the new VCC (B) over the terminal block (C).
  2. VCC is designed to install one way with the tabs aligned.
  3. Install the five screws to secure the VCC tabs to the terminal block.
  4. Tighten screws to 55 in-lb (6.2 Nm).
  5. Navigate to the 3-phase voltage selection in the controller.
  6. Select the 3-phase voltage matching the installed VCC.
  7. Verify the voltage in the menu.

Specs & values

  • VCC screws: 55 in-lb (6.2 Nm)

Full service-parts list: Generac XG03245 →, Generac XG04045 →, Generac XG04845 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.