Generac Impact-36G / NP-36G — Return Unit to Service After Storage
Maintenance · Generator set
For the Generac Impact-36G / NP-36G, from the Generac owner's manual.
Applies to: Generac GN-220 engine
Before you start
- DO NOT USE TAP WATER IN THE BATTERY
Procedure
- Check tag on engine for oil viscosity and classification; drain and refill if necessary.
- Check battery; fill cells to proper level with distilled water.
- Recharge battery to 100% state of charge or replace if defective.
- Turn OFF all electrical loads, then start the engine.
- Let engine warm up.
- Apply electrical loads to at least 50% of rated wattage capacity.
- When thoroughly warmed up, shut engine down.
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.