Generac GT-990 — Reconfiguring the Fuel System (NG to LP)

Adjustments

For the Generac GT-990, from the Generac service manual.

Applies to: Generac GT-990 engine

Before you start

  • The primary regulator for the propane supply is NOT INCLUDED with the generator.

Procedure

  1. Open the roof.
  2. Return the inlet hose and tighten clamp securely.
  3. Remove the air cleaner cover.
  4. Slide the fuel selector lever out towards the back of the enclosure.
  5. Return the air cleaner cover and tighten the two thumb screws.
  6. Close the roof.
  7. Reverse the procedure to convert back to natural gas.

Specs & values

  • A fuel pressure of 0.0178 to 0.0305 kg/cm2 (10 to 12 inches of water column) to the fuel inlet of the generator must be supplied for LP

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.