Procedure

  1. Position head gasket on the block.
  2. Position cylinder head to cylinder block.
  3. Install 10 cylinder head bolts in numerical sequence.
  4. Tighten to 70 N-m (52 lb-ft) in sequence.
  5. Retighten to 70 N-m (52 lb-ft) in sequence.
  6. Turn all head bolts an additional 90-100 degrees in sequence.

Specs & values

  • 70 N-m (52 lb-ft)
  • Additional 90-100 degrees

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.