Home›Repair guides›Generac›Adjusting No-Load Frequency for NP-50G/LP

Generac — Adjusting No-Load Frequency for NP-50G/LP

Adjustments · Governor

From a Generac service manual covering: NP-50G, NP-50LP, NP-66G/LP, Q-40G, Q-55G/LP, Q-70G/LP. Check it applies to your exact model before use.

Applies to: Generac NP-50G, Generac NP-50LP, Generac Q-40G, Generac NP-50G/LP engine

Procedure

  1. Loosen governor clamp bolt.
  2. Push spring end of governor lever clockwise to wide open throttle position of lever.
  3. Hold governor lever at wide open throttle and, with pliers, rotate governor shaft fully counterclockwise.
  4. While holding governor shaft fully clockwise and governor lever at wide open throttle, tighten governor clamp bolt to 70 inch-pounds (8 N-m).
  5. Start engine; let it stabilize and warm up at no-load.
  6. Turn adjuster nut to obtain a frequency reading of 62 Hertz.
  7. Check governor spring location in slot of governor lever.
  8. If droop is excessive, move governor spring down one slot on lever.
  9. For greater stability, move governor spring up one slot on lever.
  10. Recheck frequency reading; readjust adjuster nut if necessary to obtain 62 Hertz at no-load.
  11. When frequency is correct at no-load, check AC voltage; voltage regulator may require adjustment.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 70 inch-pounds (8 N-m)
  • 62 Hertz no-load

Full service-parts list: Generac NP-50G →, Generac NP-50LP →, Generac Q-40G →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.