For the Generac 4700 / QuietPact 40, from the Generac service manual.
Applies to: Generac 4700, Generac QuietPact 40, Generac GH-220 engine
Before you start
- Adjustment of the voltage adjust potentiometer must be done only when the unit is running at its correct governed no-load speed.
Procedure
- Run unit at correct governed no-load speed; no-load AC output frequency should be about 62.5 Hertz.
- With no load on the generator, slowly turn the voltage adjust pot on the voltage regulator until 124 VAC is measured.
- If voltage is not adjustable, proceed to Troubleshooting Problem 2.
Specs & values
- About 62.5 Hertz no-load
- 124 VAC at stated frequency
Full service-parts list: Generac 4700 →, Generac QuietPact 40 →