Generac 4700 / QuietPact 40 — Governor Adjustment

Adjustments · Engine governor

For the Generac 4700 / QuietPact 40, from the Generac service manual.

Applies to: Generac 4700, Generac QuietPact 40, Generac GH-220 engine

Procedure

  1. Loosen the governor clamp bolt.
  2. Push spring end of governor lever clockwise to wide open throttle position of lever.
  3. Hold lever at wide open throttle; rotate governor shaft fully clockwise with pliers using minimum force.
  4. While holding shaft fully clockwise and lever at wide open throttle, tighten governor clamp bolt to 70 inch-pounds (8 N-m).
  5. Start engine, let it stabilize and warm up at no-load.
  6. Turn the adjuster nut to obtain a frequency reading of 62 Hertz.
  7. If droop is excessive, move the governor spring down one slot on lever; for greater stability move it up one slot.
  8. Recheck frequency and readjust adjuster nut to obtain 62 Hertz at no-load.
  9. Check AC voltage reading; if incorrect the voltage regulator may require adjustment.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Governor clamp bolt 70 inch-pounds (8 N-m)
  • No-load frequency 62 Hertz

Full service-parts list: Generac 4700 →, Generac QuietPact 40 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.