Home›Repair guides›Generac›Changing Engine Oil

Generac 005222-0 / QT 3.9L 40kW — Changing Engine Oil

Maintenance · Engine crankcase / oil filter

For the Generac 005222-0 / QT 3.9L 40kW, from the Generac owner's manual.

Applies to: Generac QT 3.9L 40kW, Generac V-type engine

Before you start

  • NEVER OPERATE ENGINE WITH OIL BELOW THE DIPSTICK "ADD" MARK.
  • Do not overtighten the oil filter.

Parts for this job

Part numbers from the service-parts list for Generac QT 3.9L 40kW. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Remove OIL DRAIN HOSE from its retaining clip.
  2. Loosen and remove OIL DRAIN HOSE CAP. Drain oil completely into suitable container.
  3. When all oil has drained, install and tighten OIL DRAIN HOSE CAP, re-install into retaining clip.
  4. Turn OIL FILTER counterclockwise and remove. Dispose of old filter.
  5. Apply light coating of new engine oil to seal of new oil filter. Install filter and tighten by hand only.
  6. Remove OIL FILL CAP. Add recommended oil. Do not fill above dipstick FULL mark.
  7. Start engine and check for oil leaks.

Specs & values

  • Crankcase oil capacity is 4.0 U.S. quarts (3.8 liters)

Full service-parts list: Generac QT 3.9L 40kW →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →