Generac 005211-0 / 1.5L — Battery Maintenance
Maintenance
For the Generac 005211-0 / 1.5L, from the Generac owner's manual.
Applies to: Generac In Line engine
Before you start
- Storage batteries give off explosive hydrogen gas.
- Battery electrolyte fluid is an extremely corrosive sulfuric acid solution that can cause severe burns.
- Do not use any jumper cables or booster battery to crank and start the generator engine.
- Be sure the AUTO/OFF/MANUAL switch is set to the OFF position before connecting the battery cables.
Procedure
- Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.
- Check the battery fluid level of unsealed batteries and, if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER IN BATTERIES.
- Have the state of charge and condition checked with an automotive-type battery hydrometer.
Tools required
- automotive-type battery hydrometer Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- BCI Group No. 26, 525 CCA @ 0 deg. F
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.