Fischer Panda — Ventilating at first filling of fresh water cooling circuit - FCB only
Installation
From a Fischer Panda operator's manual covering: 4000, 4000s SC, Panda 4000s PMS FC, Panda 4000s PMS SC. Check it applies to your exact model before use.
Applies to: Fischer Panda 4000, Fischer Panda 4000s SC, Fischer Panda Panda_4000s, Farymann 18W430 engine
Procedure
- Fill external cooling water expansion tank with coolant; maximum fill level is max mark; open cover temporarily; keep at least 1/3 coolant during filling.
- When coolant level no longer drops, disconnect the oil pressure switch.
- Turn remote control panel on and let coolant pump run for at least 10 minutes.
- Turn remote control panel off, reconnect oil pressure switch, fill expansion tank to max and close tank.
Full service-parts list: Fischer Panda 4000 →, Fischer Panda 4000s SC →, Fischer Panda Panda_4000s →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.