Home›Repair guides›Fischer Panda›Ventilating at first filling of fresh water cooling circuit - FCB only

Fischer Panda — Ventilating at first filling of fresh water cooling circuit - FCB only

Installation

From a Fischer Panda operator's manual covering: 4000, 4000s SC, Panda 4000s PMS FC, Panda 4000s PMS SC. Check it applies to your exact model before use.

Applies to: Fischer Panda 4000, Fischer Panda 4000s SC, Fischer Panda Panda_4000s, Farymann 18W430 engine

Procedure

  1. Fill external cooling water expansion tank with coolant; maximum fill level is max mark; open cover temporarily; keep at least 1/3 coolant during filling.
  2. When coolant level no longer drops, disconnect the oil pressure switch.
  3. Turn remote control panel on and let coolant pump run for at least 10 minutes.
  4. Turn remote control panel off, reconnect oil pressure switch, fill expansion tank to max and close tank.

Full service-parts list: Fischer Panda 4000 →, Fischer Panda 4000s SC →, Fischer Panda Panda_4000s →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.