Fischer Panda — Testing generator stator winding for shorts to ground

Testing & diagnosis · stator windings

From a Fischer Panda service manual covering: AGT-DC 10000, AGT10.000-24, PMS AGT-DC 10000, Panda PMS AGT-DC 10000. Check it applies to your exact model before use.

Applies to: Fischer Panda AGT-DC 10000, Fischer Panda Panda PMS AGT-DC 10000, Kubota D722 engine

Before you start

  • Read safety instructions before working.

Procedure

  1. Ensure generator is OFF and cannot be accidentally started.
  2. Disconnect battery.
  3. Remove power terminal box cover.
  4. Remove all terminal box connections and cables.
  5. Use multimeter to check continuity between winding connections.
  6. If continuity is detected, send generator to factory or have stator rewound.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Fischer Panda AGT-DC 10000 →, Fischer Panda Panda PMS AGT-DC 10000 →, Kubota D722 engine →