Home›Repair guides›Fischer Panda›Preparation for winter storage

Fischer Panda PMS 8 mini E-TEC / Panda PMS 8 mini E-TEC — Preparation for winter storage

Maintenance · Generator

For the Fischer Panda PMS 8 mini E-TEC / Panda PMS 8 mini E-TEC, from the Fischer Panda service manual.

Applies to: Icemaster GmbH (Fischer Panda) Panda PMS 8 mini E-TEC, Kubota Z482 engine

Procedure

  1. Rinse raw water circuit with anti-freeze solution.
  2. Check anti-freeze concentration in internal cooling circuit.
  3. Clean raw water filter and check seal.
  4. Check all hoses and hose connectors.
  5. Remove impeller, grease with vaseline, store in dark place.
  6. Disassemble, check and grease vent valve.
  7. Disconnect starter battery positive and negative poles.
  8. Lubricate speed adjustment spindle with Antiseize grease.

Full service-parts list: Icemaster GmbH (Fischer Panda) Panda PMS 8 mini E-TEC →, Kubota Z482 engine →

Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.