Home›Repair guides›Fischer Panda›De-aerating of the coolant circuit

Fischer Panda PMS 8 mini E-TEC / Panda PMS 8 mini E-TEC — De-aerating of the coolant circuit

Maintenance

For the Fischer Panda PMS 8 mini E-TEC / Panda PMS 8 mini E-TEC, from the Fischer Panda service manual.

Applies to: Icemaster GmbH (Fischer Panda) Panda PMS 8 mini E-TEC, Kubota Z482 engine

Before you start

  • Do not open cooling water pump de-aerating screw while generator runs.

Procedure

  1. Stop generator before opening de-aerating points.
  2. Open de-aerating screw at cooling water pump.
  3. Open de-aerating screw at thermostat housing.
  4. Fill coolant at filler neck until level stops falling.
  5. Close filler cap and de-aerating screws.
  6. Start generator; repeat de-aeration several times.
  7. Check external expansion tank filled to max mark.

Full service-parts list: Icemaster GmbH (Fischer Panda) Panda PMS 8 mini E-TEC →, Kubota Z482 engine →

Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.