Home›Repair guides›Fischer Panda›Winter storage preparation

Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB — Winter storage preparation

Maintenance · generator

For the Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB, from the Fischer Panda operator's manual.

Applies to: Fischer Panda Panda PMS 4200 FCB, Farymann 18W430 engine

Procedure

  1. Rinse raw water circuit with anti-freeze solution.
  2. Check anti-freeze concentration in internal cooling circuit.
  3. Clean raw water filter and check seal.
  4. Check and lubricate water cock.
  5. Check hoses and hose connectors; renew if necessary.
  6. Dismount impeller, grease with vaseline, store dark; renew in spring.
  7. Check vent valve; disassemble, clean, grease or replace.
  8. Check water lock and drain water if fresh water rinse was used.
  9. Check exhaust/water separator and hose connectors for leakage.
  10. Check generator interior for leakages and dry sound cover.
  11. Spray generator and engine housings with corrosion protection oil.
  12. Disconnect starter battery positive and negative.
  13. Lubricate spindle for revolutions adjustment with Antiseize grease.
  14. Check coolant connection block for corrosion and renew if necessary.
  15. Use air dehumidifier in ship.

Full service-parts list: Fischer Panda Panda PMS 4200 FCB →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →