Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB — Ventilating the coolant circuit / freshwater
Maintenance · cooling system
For the Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB, from the Fischer Panda operator's manual.
Applies to: Fischer Panda Panda PMS 4200 FCB, Farymann 18W430 engine
Before you start
- External expansion tank should be connected and mounted at sufficient height, 600 mm over exhaust elbow union.
Procedure
- Stop generator before opening ventilating points.
- Open cooling water filler screw.
- Refill coolant until level no longer sags.
- Close screw and start generator; run about 1 minute and switch off.
- Open ventilation screw at cooling water pump pipe until water exits nonporous.
- Close screw firmly.
- Repeat de-aeration two to three times; repeat after some days.
Full service-parts list: Fischer Panda Panda PMS 4200 FCB →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.