Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB — Stopping Generator

Operation

For the Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB, from the Fischer Panda operator's manual.

Applies to: Fischer Panda Panda PMS 4200 FCB, Farymann 18W430 engine

Before you start

  • Never switch off battery until generator has stopped.

Procedure

  1. Switch off load.
  2. If load is above 70% nominal, run without load at least 5 minutes to stabilise temperature.
  3. At ambient above 25°C, run at least 5 minutes without load before stopping.
  4. Press OFF button and switch off generator.
  5. Activate additional switches such as battery switch and fuel stop valve.
  6. If necessary, close sea cock.

Full service-parts list: Fischer Panda Panda PMS 4200 FCB →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.