Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB — Stopping Generator
Operation
For the Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB, from the Fischer Panda operator's manual.
Applies to: Fischer Panda Panda PMS 4200 FCB, Farymann 18W430 engine
Before you start
- Never switch off battery until generator has stopped.
Procedure
- Switch off load.
- If load is above 70% nominal, run without load at least 5 minutes to stabilise temperature.
- At ambient above 25°C, run at least 5 minutes without load before stopping.
- Press OFF button and switch off generator.
- Activate additional switches such as battery switch and fuel stop valve.
- If necessary, close sea cock.
Full service-parts list: Fischer Panda Panda PMS 4200 FCB →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.