Home›Repair guides›Fischer Panda›Daily routine checks before starting

Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB — Daily routine checks before starting

Operation · generator

For the Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB, from the Fischer Panda operator's manual.

Applies to: Fischer Panda Panda PMS 4200 FCB, Farymann 18W430 engine

Before you start

  • Oil level must be checked daily; low oil can damage bearings.

Procedure

  1. Check engine oil level; ideal level is 2/3 of maximum.
  2. Check cooling water level in external expansion tank; keep expansion space.
  3. Open sea cock for cooling water intake.
  4. Check and clean raw water filter.
  5. Check all hose connections and hose clamps for leakage.
  6. Check all electrical lead terminal contacts are firm.
  7. Check motor and generator mounting screws are tight.
  8. Switch land electricity/generator switch to zero or switch off all load.
  9. Check automatic controls and oil pressure; generator should switch off when monitoring cable is removed.

Full service-parts list: Fischer Panda Panda PMS 4200 FCB →

Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.