Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB — Connection of 12V starter battery
Installation
For the Fischer Panda PMS 4200 FCB / Panda PMS 4200 FCB, from the Fischer Panda operator's manual.
Applies to: Fischer Panda Panda PMS 4200 FCB, Farymann 18W430 engine
Before you start
- Do not disconnect battery during operation.
- Do not use Gel-Cel batteries.
Procedure
- Connect positive battery cable directly to solenoid switch of starter; use protective tube.
- Connect battery negative to connection point next to water connection block.
- Install correctly sized fuse in positive battery line close to battery, max 12 inch/300 mm.
- Use multi-core stranded wire only; battery-to-DC-system line cross-section 25 mm².
- Protect battery lines against heat, vibration and chafing.
Specs & values
- Battery-to-DC-system line cross-section 25 mm²
Full service-parts list: Fischer Panda Panda PMS 4200 FCB →
Source: Fischer Panda operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.